Abstract
The nanoelectrospray ion source (nanoES) has recently been developed and described theoretically. It is different from conventional electrospray sources and from other miniaturized electrospray sources by (i) its 1-2 microns spraying orifice achieved by pulling the spraying capillary to a fine tip, (ii) its very low flow rate of approximately 20 nL/min and the small size of droplets it generates, and (iii) the absence of solvent pumps and inlet valves. The fabrication and operation of nanoES needles is described in detail. Solutions with up to 0.1 M salt contents could be sprayed without sheath flow or pneumatic assist. Improved desolvation in nanoES led to instrument-limited resolution of the signals of a glycoprotein and the ability to signal average extensively allowed the C-terminal sequencing of a 40 kDa protein. Extensive mass spectrometric and tandem mass spectrometric investigation of the components of an unseparated peptide mixture was demonstrated by verification of 93% of the sequence of carbonic anhydrase. A rapid and robust desalting/concentration step coupled to the nanoES procedure allows the direct analysis of impure samples such as peptide mixtures extracted after in-gel digestion.
Keywords
Affiliated Institutions
Related Publications
A metal aerosol holding chamber devised for young children with asthma
The low tidal volume and flow in preschool children may reduce the efficiency of aerosol delivery from a pressurized metered-dose inhaler (pMDI) through a traditional holding ch...
Patterning of highly oriented pyrolytic graphite by oxygen plasma etching
Patterning of highly oriented pyrolytic graphite (HOPG) was demonstrated by oxygen plasma etching of lithographically patterned substrates. Periodic arrays of islands, or holes ...
Absolute isotopic abundance ratios and the atomic weight of a reference sample of chromium
Absolute values have been obtained for the isotopic abundance ratios of a reference sample of chromium, using surface emission mass spectrometry. Samples of known isotopic compo...
Absolute isotopic abundance ratio and atomic weight of terrestrial rubidium
An absolute value hsas been obtained for the isotopic abundance ratio of terrestrial rubidium, using solid-sample thermal ionization mass spectrometry. Samples of known isotopic...
X‐ray photoelectron spectroscopy studies of chromium compounds
Abstract Photoelectron spectra of a number of chromium oxides and other compounds were studied under high spectral resolution conditions chosen to reduce the possibility of diff...
Publication Info
- Year
- 1996
- Type
- article
- Volume
- 68
- Issue
- 1
- Pages
- 1-8
- Citations
- 1838
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1021/ac9509519