Abstract
Abstract The hysteretic effects in the moisture characteristics and the hydraulic conductivity characteristics of two different glass‐bead media were measured while unsteady water flow was occurring. A gamma‐ray moisture sensor, a combination of pressure transducers and tensiometers, and a capillary‐tube flux meter were combined with a simple box‐like flow chamber for simultaneous measurement of (i) the degree of saturation, (ii) the water‐phase pressure, and (iii) the hydraulic conductivity. These quantities were recorded through out water‐pressure changes which traversed the main‐branch wetting and drying curves as well as the families of “rewet” and “redry” scanning loops. Large hysteresis was recorded in the relation of pressure to saturation or to conductivity. The relation of conductivity to saturation showed hysteresis which, though significantly larger than the experimental error, would for most practical purposes be negligible. The independent domain theory of hysteresis was used to check the relation between the “rewet” and “redry” families of moisture characteristics. By this test the theory was found to be very poorly suited to a description of these media. Two basic approximations of the theory were assumed to be responsible for this lack of applicability.
Keywords
Affiliated Institutions
Related Publications
Hysteresis in Two Sands and the Independent Domain Model
Hysteresis in the relations between moisture content, potential, and conductivity was measured on two sands, one fine grained and the other coarse and angular grained. Hydraulic...
Factors Important in the Calculation of Hydraulic Conductivity
Abstract The calculation of hydraulic conductivity by a modified Millington‐Quirk method with a matching factor gave conductivity values closely approximating experimentally mea...
A new model for predicting the hydraulic conductivity of unsaturated porous media
A simple analytic model is proposed which predicts the unsaturated hydraulic conductivity curves by using the moisture content‐capillary head curve and the measured value of the...
Soil‐Water Hysteresis Measured in a Sandy Loam and Compared with the Hysteretic Domain Model
Abstract A uniformly packed column of sandy loam soil was subjected to a controlled series of wetting and drying changes. Soil water contents were obtained from gamma ray attenu...
Calculation of Hydraulic Conductivity: A further Evaluation of some Predictive Methods
Abstract A computational method based on the pore‐interaction model of Marshall was shown to compare favorably with modified methods of Millington and Quirk and of Marshall for ...
Publication Info
- Year
- 1966
- Type
- article
- Volume
- 30
- Issue
- 2
- Pages
- 156-162
- Citations
- 202
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.2136/sssaj1966.03615995003000020008x