Abstract
In the course of an investigation of the biochemical changes following experimental liver injury we felt the need of a simple, rapid, and accurate method for determining the protein fractions in small amounts of serum. Among the simpler procedures known, the biuret reaction seemed to offer the most encouraging possibilities. Variations and improvements in the application of the biuret reaction to clinical chemistry can be traced in the works of Autenrieth (l), Hiller (2), Fine (3), Kingsley (4), and Robinson and Hogden (5). Kingsley (6) simplified the technique by adding serum directly to a “one piece” reagent. Efforts have been made to increase the stability of such biuret reagents with ethylene glycol (7), tartrate (8), and citrate (9)) We began our investigation with Kingsley’s (6) method and report briefly on the two main difficulties encountered in its use. The first is that the total protein (TP) reagent and, to a lesser extent, the albumin (ALB) reagent are not sufficiently stable. The length of time they remain so depends upon the technique of their preparation. One consequence of this variable stability is a difficulty in duplicating calibration curves with different lots of reagent. Errors may arise when results with a new reagent are read from an old calibration curve. Serious errors occur if a reagent is used after the separation of any black deposit gives evidence of deterioration. A second difficulty has been that total protein estimations made with the TP reagent and read, as prescribed, from calibration curves prepared with the ALB reagent have tended to be too low. Recorded in Table I are the results of a number of analyses in which Kingsley’s biuret procedure has been compared with the Kjeldahl method2 on both normal and ab-
Keywords
Affiliated Institutions
Related Publications
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Since 1922 when Wu proposed the use of the Folin phenol reagent for the measurement of proteins (l), a number of modified analytical procedures ut.ilizing this reagent have been...
A PHOTOMETRIC ADAPTATION OF THE SOMOGYI METHOD FOR THE DETERMINATION OF GLUCOSE
The reliability of the various Somogyi-Shaffer-Hartmann (1, 2) copper reagents for glucose determination in biological material has been established. Adaptation of these reagent...
Estimating radiocarbon calibration curves
In addition to being crucial to the establishment of archaeological chronologies,\nradiocarbon dating is vital to the establishment of time lines for many Holocene and late\nPle...
The IntCal20 Northern Hemisphere Radiocarbon Age Calibration Curve (0–55 cal kBP)
ABSTRACT Radiocarbon ( 14 C) ages cannot provide absolutely dated chronologies for archaeological or paleoenvironmental studies directly but must be converted to calendar age eq...
Estimation of surface focus<i>P</i>travel times
Abstract An iterative technique was used to locate some 400 earthquakes, estimate corrections to the Jeffreys-Bullen P travel times and estimate azimuthally dependent station ad...
Publication Info
- Year
- 1949
- Type
- article
- Volume
- 177
- Issue
- 2
- Pages
- 751-766
- Citations
- 16076
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1016/s0021-9258(18)57021-6