Abstract
The reliability of the various Somogyi-Shaffer-Hartmann (1, 2) copper reagents for glucose determination in biological material has been established. Adaptation of these reagents to calorimetric use may be accomplished by omission of the iodide and iodate in their preparation, since these interfere with the molybdate color reagents. This omission produces no especial change in the character of the reagents. KI, however, inhibits the autoreduction of the copper and in its absence an unstable reagent results. Nevertheless, if the copper is added to the rest of the reagent on the day of its use, this difficulty is avoided. When the Somogyi micro reagent (2) is used in this way with almost any of the various phosphomolybdate reagents, very satisfactory proportionality is found between color density and glucose taken over a wide range of values. However, all of the phosphomolybdate reagents tried left much to be desired in reproducibility from time to time and lacked the desired stability of color. We therefore tried various color reagents, which led to the development of a new arsenomolybdate reagent. When this reagent was used with Somogyi’s micro reagent, it gave satisfactory stability and reproducibility of color. By this means it has been possible to utilize the copper reagents in a photometric procedure for practically all the uses to which the titrimetric procedures are adapted. These include tissue sugar, glycogen, urine reduction equivalent, maltose, glucuronic acid, etc. However, diastase determinations have not been successful because of the effect of the undigested starch on the clarity of the final colored solution. The reactions involved in the molybdenum blue reaction are uncertain and beyond the scope of this report. Woods and Mellon (3) discuss and give references to the various interpretations of the reaction. Reagents-Analytical reagent grade or the equivalent. 1. Copper Reagent A. Dissolve 25 gm. of N&C03 (anhydrous), 25 gm. of Rochelle salt, 20 gm. of NaHCOs, and 200 gm. of NaiSOa (anhydrous) in about 800 ml. of water and dilute to 1 liter. Filter if necessary.’ This
Keywords
Affiliated Institutions
Related Publications
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Since 1922 when Wu proposed the use of the Folin phenol reagent for the measurement of proteins (l), a number of modified analytical procedures ut.ilizing this reagent have been...
Catalog of Four‐Color Photometry of Stars, Galaxies, and QSOs Using SDSS Filters
We present a catalog containing the measurements of 2262 sources, including 334 extended sources, 1915 point sources, and 13 known QSOs, in five SDSS passbands. Of these objects...
The Sloan Digital Sky Survey Photometric System
This paper describes the Sloan Digital Sky Survey photometric system, a new five-color (u‧ g‧ r‧ i‧ z‧) wide-band CCD system with wavelength coverage from 3000 to 11 000 Å. The ...
The Sloan Digital Sky Survey Photometric Camera
We have constructed a large format mosaic CCD camera for the Sloan Digital\nSky Survey. The camera consists of two arrays, a photometric array which uses\n30 2048 x 2048 SITe/Te...
Reproducibility and responsiveness of quality of life assessment and six minute walk test in elderly heart failure patients
Objective To examine the reproducibility and responsiveness to change of a six minute walk test and a quality of life measure in elderly patients with heart failure. Design Long...
Publication Info
- Year
- 1944
- Type
- article
- Volume
- 153
- Issue
- 2
- Pages
- 375-380
- Citations
- 10310
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1016/s0021-9258(18)71980-7