Abstract
A virtual reality (VR) calibration technique of matching a virtual environment of simulated three-dimensional (3-D) graphic models with actual camera views of the remote site task environment has been developed. This VR calibration enables high-fidelity preview/predictive displays with calibrated graphics overlay on live video. Reliable and accurate calibration is achieved by operator-interactive camera calibration and object localization procedures based on new linear/nonlinear least-squares algorithms that can handle multiple-camera views. Since the object pose becomes known through the VR calibration, the operator can now effectively use the semiautomatic computer-generated trajectory mode in addition to the manual teleoperation mode. The developed VR calibration technique and the resultant high fidelity preview/predictive displays were successfully utilized in a recent JPL/NASA-GSFC (Jet Propulsion Laboratory/Goddard Space Flight Center) telerobotic servicing demonstration. Preview/predictive displays were very useful for both noncontact and contact tasks, providing an effective VR interface with immediate visual prediction/verification to the operator. The positioning alignment accuracy achieved using four-camera views in inserting a tool into the ORU hole was 0.51 cm on the average with a 1.07 cm maximum error at 95% confidence level. Results also indicate that the object localization with two well-chosen, e.g., near orthogonal camera views, could be nearly as accurate as that with four-camera views.
Keywords
Affiliated Institutions
Related Publications
A Computational Model for the Stereoscopic Optics of a Head-Mounted Display
For stereoscopic photography or telepresence, orthostereoscopy occurs when the perceived size, shape, and relative position of objects in the three-dimensional scene being viewe...
Computer graphics: principles and practice
1. Introduction. Image Processing as Picture Analysis. The Advantages of Interactive Graphics. Representative Uses of Computer Graphics. Classification of Applications. Developm...
It is time to retire the computed tomography dose index (CTDI) for CT quality assurance and dose optimization
Arguing against the Proposition is Cynthia H. McCollough, Ph.D. Dr. McCollough is Associate Professor of Radiological Physics at the Mayo Clinic College of Medicine. She oversee...
Publication Info
- Year
- 1996
- Type
- article
- Volume
- 5
- Issue
- 2
- Pages
- 173-190
- Citations
- 45
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1162/pres.1996.5.2.173