Abstract
1. The theory of steady‐state filtration through capillary walls (Michel, 1984) has been developed and investigated in experiments on single capillaries of the frog mesentery perfused with Ringer solutions containing bovine serum albumin (BSA) and Ficoll 70. 2. In each experiment, the micro‐occlusion technique of Michel, Mason, Curry, Tooke & Hunter (1974) has been used to investigate the relation between fluid movements per unit area of capillary wall (Jv/A) and capillary pressure (Pc) under two sets of conditions in the same vessel. First, the relation has been determined following brief perfusions, where the difference in oncotic pressure across the capillary wall approximated to the perfusate oncotic pressure at all values of Pc. These results are referred to as the transient data. Secondly, the relation was investigated by estimating Jv/A at values of Pc which had been maintained constant during at least 2 min of perfusion prior to the measurement. Under these conditions the concentration of macromolecules in the pericapillary fluid was determined by the steady‐state composition of the filtrate passing through the capillary wall, and these results are referred to as steady‐state data. 3. In all fifteen capillaries investigated, the relationship between Jv/A and Pc was linear for the transient data and conspicuously non‐linear in the steady state. When Pc exceeded the oncotic pressure of the perfusate, steady‐state values for Jv/A lay slightly above but parallel to the transient values for the same vessel. At values of Pc less than the perfusate oncotic pressure, the transient data showed reabsorption of fluid from the tissues, but in the steady state either fluid movements were so small as to be undetected or slight filtration was observed. The steady‐state data followed the pattern predicted by theory. 4. The transient data were used to estimate the reflection coefficient of the capillary wall (sigma) to the macromolecular solute. In seven vessels, the mean sigma to BSA was 0.76 (S.E. of mean +/‐ 0.04) and in eight different vessels mean sigma to Ficoll 70 in the presence of BSA (10 mg ml‐1) was 0.98 (S.E. of mean +/‐ 0.05). The steady‐state data were consistent with the prediction that the oncotic pressure opposing high filtration rates approximates to sigma 2 pi c in the steady state, where pi c is the perfusate oncotic pressure.(ABSTRACT TRUNCATED AT 400 WORDS)
Keywords
Affiliated Institutions
Related Publications
Capillary filtration‐absorption balance reconsidered in light of dynamic extravascular factors
The evidence for the functional importance of extravascular Starling pressures now seems overwhelming, and when these terms are taken into account it is difficult to uphold the ...
Oncotic pressures opposing filtration across non‐fenestrated rat microvessels
We hypothesized that ultrafiltrate crossing the luminal endothelial glycocalyx through infrequent discontinuities (gaps) in the tight junction (TJ) strand of endothelial clefts ...
Properties and Structure of Aromatic Ester Solvents
This paper reports on an experimental and theoretical study of the aromatic ester solvents family. Several compounds were selected to analyze the different factors that influenc...
Hydrocortisone Preserves the Vascular Barrier by Protecting the Endothelial Glycocalyx
Background Hydrocortisone protects against ischemia-reperfusion injury, reduces paracellular permeability for macromolecules, and is routinely applied in the prevention of inter...
The motion of long bubbles in tubes
A long bubble of a fluid of negligible viscosity is moving steadily in a tube filled with liquid of viscosity μ at small Reynolds number, the interfacial tension being σ. The an...
Publication Info
- Year
- 1987
- Type
- article
- Volume
- 388
- Issue
- 1
- Pages
- 421-435
- Citations
- 132
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1113/jphysiol.1987.sp016622