Abstract
Abstract We have developed practical methods for evaluating the magnitude of the random errors in radioimmunoassay dose--response variables, and the relationship between this error and position on the dose--response curve. This is important: to obtain appropriate weights for each point on the dose--response curve when utilizing least-squares curve-fitting methods; to evaluate whether the standards and the unknowns are subject to error of the same magnitude; for quality-control purposes; and to study the sources of errors in radioimmunoassay. Both standards and unknowns in radioimmunoassays for cAMP and cGMP were analyzed in triplicate. The same mean (Y), sample standard deviation, sy, and variance (2-y) of the response variable were calculated for each dose level. The relationship between s 2-y and y was calculated utilizing several models. Results for standards and unknowns from several assays were pooled, and a curve smoothing procedure was used to minimize random sampling errors. This pooling increased the reliability of the analysis, and confirmed the presence of the theoretically predicted nonuniformity of variance. Thus, the calculation of results from these radioimmunoassays should utilize a weighted least-squares curve-fitting program. These analyses have been computerized, and can be used as a "pre-processor" for programs for routine analysis of results of radioimmunoassay.
Keywords
Related Publications
Use and Interpretation of Common Statistical Tests in Method-Comparison Studies
Abstract We have studied the usefulness of common statistical tests as applied to method comparison studies. We simulated different types of errors in test sets of data to deter...
A Computer Program for Radiocarbon Age Calibration
The calibration curves and tables given in this issue of RADIOCARBON form a data base ideally suited for a computerized operation. The program listed below converts a radiocarbo...
Principal Component Analysis Approach for Modeling Sulfur K‐XANES Spectra of Humic Acids
Quantitative application of x‐ray absorption near edge structure (XANES) spectroscopy to soils and other geochemical systems requires a determination of the proportions of multi...
Characterizing aquatic dissolved organic matter.
Standards for reporting C-14 age determinations are discussed. All dates should be related either directly or indirectly to the NBS oxalic acid standard. Corrections for isotopi...
Random sample consensus
A new paradigm, Random Sample Consensus (RANSAC), for fitting a model to experimental data is introduced. RANSAC is capable of interpreting/smoothing data containing a significa...
Publication Info
- Year
- 1976
- Type
- article
- Volume
- 22
- Issue
- 3
- Pages
- 350-358
- Citations
- 238
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1093/clinchem/22.3.350