Abstract
This study evaluated the ability of biodegradable implants fabricated from polymers and co-polymers of polylactic acid (PLA) and polyglycolic acid (PGA) to induce regeneration of surgically created defects in the dog esophagus. The study utilized 12 mongrel dogs that had a 5 cm segment of the esophagus removed. Implants were fabricated by spray casting the polymers on a spinning Teflon mandril. The defects were repaired by suturing the biodegradable implants to the proximal and distal ends of the esophagus. Ten of the dogs were sacrificed from 3 days to 8 weeks after surgery while 1 of the dogs died after 3 years and 1 dog was sacrificed 4 years after graft placement. Endoscopic and histologic examination of the grafts 3 days after placement showed minimal inflammatory response and an apparent seal between the esophagus and implant at the suture lines. Two weeks after surgery a fibrous connective tissue sheath, continuous with the proximal and distal segments of the esophagus, could be seen surrounding the graft. One month after placement, the implants were partially degraded leaving a connective tissue repair continuous with the proximal and distal ends of the esophagus. The repair area was lined with epithelium and enabled the dogs to drink freely and eat semisolid foods. In conclusion, it has been shown that it is possible to fabricate a biodegradable implant which can stimulate regeneration of a hollow organ and which is compatible with long term survival.
Keywords
Affiliated Institutions
Related Publications
p53 Mutations in Human Cancers
Mutations in the evolutionarily conserved codons of the p53 tumor suppressor gene are common in diverse types of human cancer. The p53 mutational spectrum differs among cancers ...
Body Mass Index and Risk of Adenocarcinomas of the Esophagus and Gastric Cardia
Increasing prevalence of obesity in the United States population may have contributed to the upward trends in esophageal and gastric cardia adenocarcinomas.
Wear of highly crosslinked polyethylene acetabular components
This scoping review confirmed the low wear rates of XLPE in THA, as measured by RSA. We make recommendations to enhance the standardization of reporting of RSA wear results, whi...
Bioceramics: From Concept to Clinic
Ceramics used for the repair and reconstruction of diseased or damaged parts of the musculo‐skeletal system, termed bioceramics, may be bioinert (alumina, zirconia), resorbable ...
Publication Info
- Year
- 1989
- Type
- article
- Volume
- 17
- Issue
- 3
- Pages
- 291-314
- Citations
- 9
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.3109/10731198909118286