Abstract

The safe and stable operation of distribution networks relies on the real-time monitoring, analysis, and feedback of power quality data. However, with the continuous advancement of distribution network construction, the number of distributed power electronic devices has increased significantly, leading to frequent power quality issues such as voltage fluctuations, harmonic pollution, and three-phase unbalance in distribution terminals. Therefore, the augmentation and processing of power quality data have become crucial for ensuring the stable operation of distribution networks. Traditional methods for augmenting and processing power quality data fail to consider the differentiated characteristics of burrs in signal sequences and neglect the comprehensive consideration of both time-domain and frequency-domain features in disturbance identification. This results in the distortion of high-frequency fault information, and insufficient robustness and accuracy in identifying Power Quality Disturbance (PQD) against the complex noise background of distribution networks. In response to these issues, we propose a power quality data augmentation and processing method for distribution terminals considering high-frequency sampling. Firstly, a burr removal method of the sampling waveform based on a high-frequency filter operator is proposed. By comprehensively considering the characteristics of concavity and convexity in both burr and normal waveforms, a high-frequency filtering operator is introduced. Additional constraints and parameters are applied to suppress sequences with burr characteristics, thereby accurately eliminating burrs while preserving the key features of valid information. This approach avoids distortion of high-frequency fault information after filtering, which supports subsequent PQD identification. Secondly, a PQD identification method based on a dual-channel time–frequency feature fusion network is proposed. The PQD signals undergo an S-transform and period reconfiguration to construct matrix image features in the time–frequency domain. Finally, these features are input into a Convolutional Neural Network (CNN) and a Transformer encoder to extract highly coupled global features, which are then fused through a cross-attention mechanism. The identification results of PQD are output through a classification layer, thereby enhancing the robustness and accuracy of disturbance identification against the complex noise background of distribution networks. Simulation results demonstrate that the proposed algorithm achieves optimal burr removal and disturbance identification accuracy.

Affiliated Institutions

Related Publications

Publication Info

Year
2025
Type
article
Volume
18
Issue
24
Pages
6426-6426
Citations
0
Access
Closed

External Links

Social Impact

Social media, news, blog, policy document mentions

Citation Metrics

0
OpenAlex

Cite This

Ruijiang Zeng, Zhiyong Li, Haodong Liu et al. (2025). Power Quality Data Augmentation and Processing Method for Distribution Terminals Considering High-Frequency Sampling. Energies , 18 (24) , 6426-6426. https://doi.org/10.3390/en18246426

Identifiers

DOI
10.3390/en18246426