Abstract
Abstract Acquisition‐weighting improves the localization of MRI experiments. An approach to acquisition‐weighting in a purely phase‐encoded experiment is presented that is based on a variation of the sampling density in k ‐space. In contrast to conventional imaging or to accumulation‐weighting, where k ‐space is sampled with uniform increments, density‐weighting varies the distance between neighboring sampling points Δ k to approximate a given radial weighting function. A fast, noniterative algorithm has been developed to calculate the sampling matrix in one, two, and three dimensions from a radial weighting function w(k ), the desired number of scans NA tot and the nominal spatial resolution Δ x nom . Density‐weighted phase‐encoding combines the improved shape of the spatial response function and the high SNR of acquisition‐weighting with an extended field of view. The artifact energy that results from aliasing due to a small field of view is substantially reduced. The properties of density‐weighting are compared to uniform and to accumulation‐weighted phase‐encoding in simulations and experiments. Density‐weighted 31 P 3D chemical shift imaging of the human heart is shown which demonstrates the superior performance of density‐weighted metabolic imaging. Magn Reson Med 50:1266–1275, 2003. © 2003 Wiley‐Liss, Inc.
Keywords
Affiliated Institutions
Related Publications
Reduced aliasing artifacts using variable-densityk-space sampling trajectories
A variable-density k-space sampling method is proposed to reduce aliasing artifacts in MR images. Because most of the energy of an image is concentrated around the k-space cente...
<i>k‐t</i> BLAST and <i>k‐t</i> SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Abstract Dynamic images of natural objects exhibit significant correlations in k ‐space and time. Thus, it is feasible to acquire only a reduced amount of data and recover the m...
Single breath‐hold whole‐heart MRA using variable‐density spirals at 3t
Abstract Multislice breath‐held coronary imaging techniques conventionally lack the coverage of free‐breathing 3D acquisitions but use a considerably shorter acquisition window ...
Sparse MRI: The application of compressed sensing for rapid MR imaging
Abstract The sparsity which is implicit in MR images is exploited to significantly undersample k ‐space. Some MR images such as angiograms are already sparse in the pixel repres...
Undersampled projection reconstruction applied to MR angiography
Undersampled projection reconstruction (PR) is investigated as an alternative method for MRA (MR angiography). In conventional 3D Fourier transform (FT) MRA, resolution in the p...
Publication Info
- Year
- 2003
- Type
- article
- Volume
- 50
- Issue
- 6
- Pages
- 1266-1275
- Citations
- 68
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1002/mrm.10647