Abstract
An algorithm (SEQPEP) that aids in the interpretation of high-energy (greater than 1 kV) collision-induced dissociation mass spectra of peptide ions generated by fast atom bombardment (FAB) ionization is described. The only required input is a list of product ion masses and relative abundances generated by the mass spectrometer data system, the mass of the precursor [M + H]+ ion, and the mass of any C-terminal modification, if present (e.g., amide). Possible N-terminal modifications and amino acid compositions are not required as input. In the output, sequences are ranked according to the fraction of total product ion current that can be accounted for as either sequence-specific or non-sequence-specific fragment ions. These are listed by ion type. One of the major advantages of this program over algorithms described earlier is the incorporation of ion types more recently discovered. Also, this program is much faster, requiring less than 5 min of central processing unit time for an input of as many as 100 product ions. The results obtained from 50 peptides, including some generated when sequencing a protein of previously unknown structure, are discussed.
Keywords
Affiliated Institutions
Related Publications
An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein database
A method to correlate the uninterpreted tandem mass spectra of peptides produced under low energy (10-50 eV) collision conditions with amino acid sequences in the Genpept databa...
Protein sequencing by tandem mass spectrometry.
Methodology for determining amino acid sequences of proteins by tandem mass spectrometry is described. The approach involves enzymatic and/or chemical degradation of the protein...
Method to Correlate Tandem Mass Spectra of Modified Peptides to Amino Acid Sequences in the Protein Database
A method to correlate uninterpreted tandem mass spectra of modified peptides, produced under low-energy (10-50 eV) collision conditions, with amino acid sequences in a protein d...
The Characteristics of Peptide Collision-Induced Dissociation Using a High-Performance MALDI-TOF/TOF Tandem Mass Spectrometer
A new matrix-assisted laser desorption/ionization (MALDI) time-of-flight/time-of-flight (TOF/TOF) high-resolution tandem mass spectrometer is described for sequencing peptides. ...
MacProMass: A computer program to correlate mass spectral data to peptide and protein structures
A program known as MacProMass has been written for Macintosh computers to assist in the analysis of mass spectral data of peptides and proteins. The program employs a user frien...
Publication Info
- Year
- 1989
- Type
- article
- Volume
- 18
- Issue
- 11
- Pages
- 945-957
- Citations
- 111
- Access
- Closed
External Links
Social Impact
Social media, news, blog, policy document mentions
Citation Metrics
Cite This
Identifiers
- DOI
- 10.1002/bms.1200181102