Abstract

ABSTRACT Objectives Regular exchange of percutaneous endoscopic gastrostomy (PEG) catheters is crucial for preventing infection and maintaining function; however, procedure‐related complications and patient discomfort remain major concerns. This study aimed to compare the clinical outcomes of the conventional Ideal Button with those of the newly developed Ideal Button ZERO (Olympus Corporation). Methods In this retrospective observational study, we included 82 PEG catheter exchange procedures, performed in 42 patients. Because some patients underwent repeated exchanges, analyses were conducted on a per‐procedure basis. Patients were categorized into two groups: Group N (conventional to conventional Ideal Button exchange, n = 33) and Group Z (exchange to Ideal Button ZERO, n = 49). Group Z was further subdivided into subgroups Z1 (conventional to ZERO, n = 29) and Z2 (ZERO to ZERO, n = 20). The outcomes included the procedure time, complication rates (procedure‐related and postoperative), and family satisfaction score. Results Procedure‐related complications occurred only in Group Z (0/33 vs. 6/49; 0% vs. 12.2%) ( p = 0.076). Postoperative complication rates were similar between the groups (Group N 6/33 [18.2%] vs. Group Z 9/49 [18.4%], p = 1.00). However, procedure time was shorter in Group Z than in Group N (8.24 ± 5.21 vs. 6.14 ± 4.28 min, p = 0.049). Family satisfaction scores showed no significant differences between the groups (Group N: 3.88 ± 1.52 vs. Group Z: 3.94 ± 1.39, p = 0.854). Conclusions The new Ideal Button ZERO showed a reduced procedure time; however, it revealed a trend toward higher procedure‐related complications without clear superiority over conventional devices. Improved proficiency with the new device may reduce complication rates, warranting further investigation as its adoption increases. Trial Registration 2025‐047

Keywords

catheterizationendoscopygastrostomypercutaneous endoscopic gastrostomypostoperative complications

Affiliated Institutions

Related Publications

Publication Info

Year
2025
Type
article
Volume
6
Issue
1
Citations
0
Access
Closed

Citation Metrics

0
OpenAlex
0
Influential

Cite This

Kazuya Miyaguchi, Hisashi Matsumoto, Yuki Shiko et al. (2025). Comparative Analysis of Conventional Ideal Button Versus New Ideal Button ZERO for Percutaneous Endoscopic Gastrostomy Catheter Replacement. DEN Open , 6 (1) . https://doi.org/10.1002/deo2.70261

Identifiers

DOI
10.1002/deo2.70261
PMID
41383354
PMCID
PMC12690300

Data Quality

Data completeness: 81%